Critical State Monitor

  • ID:  Microsoft.SQLServerAppliance.PDW2.Network.ConnectivityStateMonitor.Critical
  • Description:  This monitor detects if Connectivity Component is in Critical state.
  • Target:  SQL 2012 PDW Network Connectivity Component
  • Enabled:  Yes

Operational States

Name State Description
Ok Success  
Critical Warning  

Overridable Parameters

Parameter Name Default Value Description Override
Interval (sec) 900  
Synchronization Time    
Timeout (sec) 600  

Alert Details

Monitor State Message Priority Severity Auto Resolution
Critical (Warning) Network connection has CRITICAL status Medium Warning Yes

Run As Profiles

Name
Default

Monitor Knowledgebase

Summary

The network adapter connection is reporting a critical state that typically means at least one port has failed. If both ports fail on this adapter then the cluster service will trigger a failover event for the node.

Causes

This is caused because of one of the following reasons:

  • Network is disconnected (vendor status: 0).

  • Hardware is not present (vendor status: 4).

  • Hardware has been disabled (vendor status: 5).

  • Media is disconnected (vendor status: 7).

  • Authentication has failed (vendor status: 10).

  • Invalid address was used (vendor status: 11).

  • Credentials are required but not supplied (vendor status: 12).

For more details, view the component's connectivity_connection_status property in the PDW Admin Console or query the sys.dm_pdw_component_health_status DMV.

Resolutions

To diagnose this issue:

1) Use the sys.dm_pdw_errors and sys.dm_pdw_os_event_logs DMVs to check for relevant failures.

2) Verify if this caused a port failure. To do this, use a Windows administrator account to login to the Host node. Open a command window and ping the IP address for the affected network adapter.

3) If you cannot ping the network adapter, the port may have failed. Access the physical appliance to check the cable connections. Check the network switch logs for this port to determine if the switch has issues.

To resolve this issue, contact Microsoft support and provide them with the information you have gathered. Microsoft Support will help you to understand the failure and help you to bring the network adapter back online or into a healthy state.

External References
This monitor does not contain any external references.

See Also for SQL Server Parallel Data Warehouse Appliance Management Pack


Downloads for SQL Server Parallel Data Warehouse Appliance Management Pack

AZURE OPTIMIZATION ASSESSMENT GET STARTED
MIGRATION TO AZURE GET STARTED
SYSTEM CENTER MIGRATION TO AZURE GET STARTED
MIGRATION TO AZURE FOR SQL AND WINDOWS 2008 GET STARTED