The storage array is reporting a non-critical warning. The storage system might be experiencing an issue that will degrade performance.
You need to check the temperature status or power supply status of this storage system.
Additionally, if the side panel for the storage system is removed, the air flow changes could result in improper cooling of the drives and affect the temperature status.
For more details, view the storage_global_status property in the PDW Admin Console or query the sys.dm_pdw_component_health_status DMV.
Contact Microsoft Support and provide them with the alert name and details.
To diagnose this issue:
1) Microsoft Support will require Windows administrator access to the affected PDW Host node in order to access the vendor’s integrated system user interface for the storage processor in question.
2) Use the PDW Admin Console or health DMVs to view the current values for the properties of the storage enclosure.
To resolve this issue, Microsoft Support will contact the vendor’s hardware support team. Depending on the problem, the vendor might require physical access to the appliance to replace one or more hard disks.