• Management Pack:  SCOM 2016
  • MP Version:  1.0
  • Released:  10/19/2018
  • Publisher:  Microsoft

Data Access Service - Port Availability deprecated Monitor

  • ID:  Microsoft.SystemCenter.SDKService.PortAvailability
  • Description:  Monitors the port availability of the Data Access service.
  • Target:  Root Management Server Emulator
  • Enabled:  No

Operational States

Name State Description
The Data Access service port is unavailable Error  
The Data Access service port is available Success  

Alert Details

Monitor State Message Priority Severity Auto Resolution
The Data Access service port is unavailable (Error) Data Access service unable to acquire port deprecated High Critical Yes

Run As Profiles

Name
Default

Monitor Knowledgebase

Summary

The Data Access service is unable to initialize because port 5724 is in use. The Data Access service must be able to use 5724 as this is the port used by the consoles as well as other Operations Manager components to communicate with the Data Access service. When the Data Access service is not running, users will not be able to use the Operations Console, Web Console, or Command Shell. Any connectors to 3rd party management systems will not work as well.

Causes

Another application is using port 5724.

Resolutions

Run netstat.exe –a to see what process is using port 5724.

External References